BY08IIDC-40 SPD Class T2 40KA DC Surge Protective Device

The BY08IIDC-40 Series T2 DC Surge Protective Device (SPD) is designed for use in string boxes and inverters. It features 2P and 3P configurations and provides surge protection for DC circuits with voltage ratings of 600VDC, 1000VDC, and 1500VDC. Equipped with high-energy MOV, it offers discharge currents of 20kA-40kA, effectively protecting equipment from voltage surges and transients. This device ensures the safe operation of photovoltaic systems by preventing damage from lightning or other high-voltage spikes.

    product detail

    Product Features 

    • The BY08IIDC-40 Series T2 DC Surge Protective Device (SPD) is designed to protect photovoltaic systems, specifically used in string boxes and inverters, from electrical surges and transients. This surge protective device comes in 2P and 3P configurations and is engineered to handle DC circuits with voltage ratings of 600VDC, 1000VDC, and 1500VDC, making it highly versatile for various solar power installations.
    • Equipped with high-energy Metal Oxide Varistor (MOV) technology, the BY08IIDC-40 series SPD is capable of effectively clamping high-voltage surges and dissipating excessive energy. This advanced MOV technology ensures rapid response to over-voltage events, preventing damage to sensitive equipment. The device is rated to handle discharge currents ranging from 20kA to 40kA, providing robust protection against large surge events such as lightning strikes or electrical grid disturbances.
    • The primary function of the BY08IIDC-40 series SPD is to safeguard critical components in photovoltaic systems, such as inverters and string boxes, from transient over-voltage conditions that can cause irreparable damage. By redirecting excess electrical energy safely to the ground, this device helps maintain the operational integrity of the solar power system, ensuring long-term reliability and performance.

    Technical Parameters

    No. of Poles 2P, 3P
    Location of Use String box, inverter
    Mode of Protection (DC+)-PE, (DC-)-PE, (DC+)-(DC-)
    Protective Elements High Energy Mov
    Maximum Continuous Operating DC Voltage Ucpv 600V 1000V 1500V
    Nominal Discharge Current (8/20µs) In 20kA
    Total Discharge Current (8/20µs) ITotal 40kA
    Maximum Discharge Current (8/20µs) Imax 40kA
    Voltage Protection Level (2P) Up 2.6kV 4.0kV -
    Voltage Protection Level (3P) Up - 4.0kV 5.2kV
    Response Time tA ≤25ns

    Dimensions

    图片6.png